Tea packaging machine is suitable for automatic packaging of seeds, medicine, health products, tea and other materials. This machine can make the simultaneous packaging of inner and outer bags. It can automatically complete the bag making, measuring, filling, sealing, slitting, counting and other processes. With moisture-proof, odor-proof, fresh-keeping and other functions,it has a wide range of packaging, replacing manual packaging, realizing packaging automation for large enterprises, small and medium-sized enterprises, improving production efficiency in all walks of life, and significantly reducing costs.

Failure and repair

1. Tea bag Fault reason: the pressure valve is broken or blocked; the pressure gas path is not smooth.
Treatment method: replace or clean the pressure valve; straighten and clear the pressure path.

2. The cause of large fume of vacuum pump oil:the suction filter is blocked or polluted; the pump oil is polluted;
Solution of the oil returning valve is blocked : clean or replace the exhaust filter; replace with new oil; clean the oil returning valve.

3. The cause of the vacuum pump fuel injection failure: the o-ring of the suction valve falls off; the rotary disc wear method:
Unplug the vacuum tube on the pump nozzle, remove the suction nozzle, take out the compression spring and the suction valve, and gently stretch the O-type Turn it several times, re-insert it into the groove, and then install it; change the rotor

4. Do not bleed. Reason for failure:
The cooling time relay is broken; the bleed valve circuit is short-circuited; the bleed valve is stuck or burned out. Solution: Replace the time relay; find and connect it; remove it for cleaning or replacement.

5. Causes of large noise failure:
The vacuum pump coupling is worn or broken; the exhaust filter is blocked or installed in an incorrect position; the method of leakage is: replace the vacuum pump; clean or change the exhaust filter and install it correctly; check whether the bleed valve Leaks and eliminates.

6. No heating Cause of failure: The heating bar is burnt out; the heating time relay is burned out; the heating line is burned out and the heating transformer is broken.
Treatment method: replace the heater; replace the heating line and install it firmly; replace the heating transformer

7. Vacuum pump oil leakage Reason: oil return valve is blocked; oil window is loose
Solution: remove oil return valve and clean; after oil is drained, remove oil window and wrap raw material belt or thin plastic film.

8. Low vacuum causes: pump oil is contaminated, too little or diluted; pumping time is too short; the suction filter is blocked.
Treatment method: clean the vacuum pump and replace the vacuum pump oil; extend the pumping time; clean or replace the exhaust filter .